Bipolar Water Electrolysis

Bipolar Water electrolysis type Hydrogen generators are the preferred systems for simple, reliable and clean production of Hydrogen. Customer only needs to provide water and power supply and our systems deliver high purity, high pressure Hydrogen.

MVS Engineering

TECHNICAL FACTS

01

Flow Range

We design and manufacture systems ranging from 5 to 500 Nm3/hr in a single train. If higher capacity is required, we recommend multiple systems.

02

Hydrogen Purity

99.9999% purity Hydrogen is delivered by our high purity bipolar electrolysis units. We also offer a low purity option delivering hydrogen at 99.8% purity.

03

Dew Point

MVS Hydrogen generators deliver very dry gas, with dew point as low as (-) 60°C. We also offer measuring instruments for online detection of gas dryness.

04

Pressure

Hydrogen gas is delivered from our systemsat 15 kg/cm2g without the need of a booster compressor. This pressure satisfies the requirement of the majority of our customers. We offerbooster compressorfor customersrequiring Hydrogen gas at a higher pressure.

MVS Hydrogen Generators

MVS Engineering

كيف تعمل مولدات غاز الهيدروجين

يتولد غاز الهيدروجين من الماء منزوع الاملاح او الايونات كمصدر اساسى كما فى المعادله :

 2H2O = 2H2 + O2

حيث يمر الماء خلال وحدة الفصل الكهربى التى تعمل بالتيار المستمر ثم ينفصل الماء الى اكسجين وهيدروجين, حيت يتم تصريف غاز الاكسجين الى الهواء الجوى بطريقة امنه ويستخلص غاز الهيدرجين بضغط عالى للاستخدام مباشرة من وحدة التوليد بعد تجفيفه من اى بخار ماء عبر مروره على المجفف.
وتتدع شركة ام فى اس العملاء اللذين يريدون ملئ الاسطوانات بغاز الهيدروجين بوحد ملئ كامله عباره عن ضاغط هيدروجين ذو ضغط عال.

الشركات المساهمه

توجد هناك شراكه فعليه بين شركة ام فى اس الهنديه وشركة بروتون الامريكيه والتى تعد من اكبر مصنعى اغشية التنقيه المتقدمه على مستوى العالم وقد تم بيع اكثر من 2500 جهاز عالميا وهناك فى الهند وحدها اكثر من 30 جهاز يعمل بكفاءه .

MVS Engineering
MVS Engineering

SAFETY

MVS alkaline bipolar water electrolysis Hydrogen generators have advanced monitoring systems ensuring plant operational safety. The systems safely depressurize and shut down in the case of abnormal operation.
Among the many interlocks available in our systems, a few important ones are:

  • Hydrogen leakage detection in plant room
  • Operating pressure of H2 generator
  • Operating temperature
  • Hydrogen purity
  • Oxygen purity
  • Oxygen level in Hydrogen gas
  • Dew point of Hydrogen gas
  • Instrument air pressure
  • Cooling water pressure
  • Pressure after Hydrogen regulating valve
  • Rectifier fault

APPLICATIONS

Water Electrolysis Hydrogen Generators are used in:

  • Power plants Generator cooling
  • Gas chromatography
  • Semiconductor manufacturing
  • Meteorological (Weather) balloons filling
  • Metallurgical processing (annealing, brightening, sintering)
  • Hydrogenation of fats (food processing)
  • Leak detection in air conditioning industry
  • Chemicals processing
  • Refineries and Pilot plants
  • Chemical Vapour Deposition (CVD) for diamond industry